CI-CGA Pad Layout (Pb90Sn10 columns)
Post Date:
07/16/07
Question:
What is the recommended pad layout for the CI-CGA packages (with Sn10Pb90 columns) offered with e2v Broadband Data Conversion devices?
Answer:
Description
Dimensions
e2v Rules
mm
mil
Component Land Pad Diameter (Pad)
--
0.89
35
Solder Land Diameter
L
0.75
29.5
Opening in Solder Mask Diameter
M
0.85
33.5
Solder (Ball) Land Pitch
e
1.27
50
Line Width Between Via and Land
W
0.51
20
Distance Between Via and Land
D
0.71
28
Via Land Diameter
VL
0.66
26
Through Hole Diameter
VH
0.38
15